Previous Article | Next Article ![]()
Journal of Virology, January 2008, p. 428-434, Vol. 82, No. 1
0022-538X/08/$08.00+0 doi:10.1128/JVI.00638-07
Copyright © 2008, American Society for Microbiology. All Rights Reserved.

National AIDS Research Institute,1 B. J. Medical College, Pune, India2
Received 26 March 2007/ Accepted 8 October 2007
|
|
|---|
|
|
|---|
Several investigators have documented the protective role of an alloimmune response against HIV-1. An alloimmune response at mucosal sites has been found to confer resistance to HIV-1 infection (3, 20). Among several therapeutic HIV-1 vaccine trials, instances of apparent clinical benefit were associated with the usage of vaccine candidates that contained host cell antigens and acted in accordance with the principles of alloimmunization (5, 6). Various soluble factors (CD8 suppressor factor, β-chemokines, anti-CCR5 antibodies) produced during the alloimmune response have been found to mediate protection against HIV-1 (37-39). Alloimmunization has been suggested as a strategy for the development of vaccines against HIV/AIDS (13, 28, 29). Anti-HLA antibody-mediated HIV-1 neutralization may be one of the potential mechanisms of protection induced after alloimmunization (13). In some studies, however, no protective role of anti-HLA antibodies against HIV-1 was observed. Anti-HLA alloantibodies found in children did not correlate with a lack of HIV-1 transmission from the infected mother (16). Similarly, the presence of anti-HLA antibodies did not correlate with resistance to HIV-1 infection by female commercial sex workers in the Nairobi cohort (17). The HIV-1-neutralizing activity demonstrated by exposed but persistently seronegative individuals did not correlate with the presence of anti-HLA antibodies (15). In a study reported by Polyanskaya et al. (21), anti-major histocompatibility complex antibody responses to simian B cells did not show protection of macaques against SIVmac infection.
Due to conflicting evidence from different studies, the role of anti-HLA antibodies in protection against HIV-1 has remained inconclusive (18). Potential mechanisms of protection against HIV-1 are still under investigation. We assessed human anti-HLA antibodies for protection against HIV-1 by testing anti-HLA antibody-positive plasma against HIV-1 virions carrying HLA types with matching specificities.
|
|
|---|
Eight to 10 ml of blood was collected in EDTA Vacutainers from all women and their husbands. Plasma and peripheral blood mononuclear cells (PBMCs) were separated by Ficoll-Hypaque density gradient centrifugation. Plasma and PBMCs were aliquoted and stored at –70°C and –156°C, respectively.
Screening for anti-HLA antibodies by ELISA. Plasma from multiparous women was tested for anti-HLA antibodies. Anti-HLA IgG antibodies were detected by commercially available enzyme-linked immunosorbent assay (ELISA) kits (QuikScreen and B-Screen; GTI, Brookfield, WI) according to the manufacturer's instructions. QuikScreen and B-Screen ELISA kits consist of microwell plates coated with purified genetically diverse class I and class II HLA proteins, respectively. In brief, 1/2-diluted plasma and positive and negative controls (provided with the kit) were added to separate wells in duplicate, allowing anti-HLA antibodies to bind to immobilized HLA proteins. Anti-HLA antibodies were detected using anti-human IgG conjugated with alkaline phosphatase and p-nitrophenyl phosphate as an enzyme substrate. Plasma samples showing absorbances greater than or equal to twice the mean absorbance for two negative-control wells (cutoff) were considered positive for the presence of anti-HLA antibodies, according to the manufacturer's instructions.
Binding of anti-HLA antibodies to the lymphocytes of the husband. Plasma samples from 14 women that contained anti-HLA antibodies were tested against PBMCs from their respective husbands for binding antibodies. The husband's PBMCs (2 x 105) were incubated with the wife's plasma at room temperature for 45 min, and antibodies bound to lymphocytes were detected by a fluorescein isothiocyanate (FITC)-labeled anti-human IgG antibody (Bangalore Genei, India). Stained cells were fixed in 3% formaldehyde (prepared in phosphate-buffered saline) and analyzed on a flow cytometer (FACsort; Becton Dickinson) using CellQuest software. An electronic gate was formed for lymphocytes based on their forward and side scatter. Ten thousand cells within the gate were acquired and analyzed. A pool of plasma samples from 12 healthy, HIV-seronegative individuals without any known factor for the induction of anti-HLA antibodies such as pregnancy or transplantation was used as the negative control. Specific median fluorescence intensity (sMFI) was calculated as the MFI for the test divided by the MFI for the control. All plasma samples were heat inactivated at 56°C for 30 min before use and were tested at a 1/20 dilution. All plasma samples were also tested against autologous PBMCs.
To confirm that the antibodies that bound to the husband's PBMCs were HLA specific, heat-inactivated plasma samples (0.3 ml at a 1/2 dilution) from three women, 40W, 43W, and 65W, were each incubated with the respective husband's PBMCs (3 x 106) at 37°C for 1 h. After incubation, the mixture was centrifuged, and the plasma supernatant was tested for anti-HLA antibodies and anti-cytomegalovirus (CMV) antibodies (used as an unrelated control) (Plateia CMV IgG kit; Bio-Rad, France). The plasma samples of 40W and 43W were tested at a 1/20 dilution, whereas the plasma of 65W was tested at a 1/2 dilution, for anti-HLA antibodies. All plasma samples were tested at a 1/100 dilution for antibodies against CMV.
HIV-1 culture in the husband's PBMCs. An HIV-1 subtype C, CCR5-tropic, neutralization-sensitive (12) primary isolate (VB49) obtained from the virus repository of the National AIDS Research Institute, Pune, India, was propagated in PBMCs from the husbands of all women carrying anti-HLA antibodies. The virus was also cultured in PBMCs from two women (28W and 49W). PBMCs were stimulated with phytohemagglutinin (5 µg/ml) for 48 h. Stimulated cells (8 x 106 to 10 x 106) were infected with 200 50% tissue culture infective doses of the virus. After overnight adsorption, cells were washed to remove cell-free virus and were cultured in an interleukin-2-containing (20 U/ml) medium. The culture supernatant (0.2 ml) was collected immediately after resuspension of the cells in interleukin-2-containing medium (day zero) and at 7 days of incubation at 37°C under a 5% CO2 atmosphere. Culture supernatants collected on day zero and day 7 were tested for HIV-1 p24 protein with an ELISA kit (Vironostika HIV-1 antigen micro-ELISA system; Biomerieux, The Netherlands). The culture supernatant was harvested on day 7, when a high concentration of p24 antigen (absorbance, >2 at a 1/200 dilution) was detected. The supernatant was centrifuged, aliquoted, and stored at –70°C. The amounts of these virus stocks ranged from 2.6 x 103 to 257 x 103 50% tissue culture infective doses/ml (determined as described in the NIAID ACTG manual [1]).
Determination of HIV-1-neutralizing activity of anti-HLA antibodies.
The ability of anti-HLA antibody-positive plasma from multiparous women to neutralize an HIV-1 strain carrying HLA proteins with matching specificities was investigated. HIV-1-neutralizing activity was detected by using CCR5+ GHOST cells, which express green fluorescent protein under the control of HIV-2 Tat, as target cells (35). Anti-HLA antibody-positive plasma was incubated with HIV-1 (at a predetermined dilution that produces
1,000 fluorescent cells at the end of the assay) for 1 h at 37°C under a 5% CO2 atmosphere. The virus-antibody mixture was used to infect the GHOST cells in the presence of DEAE-dextran (8 µg/ml). The plate was incubated at 37°C under a 5% CO2 humidified atmosphere for 4 days. After incubation, cells were harvested, fixed in 2% formaldehyde, and analyzed on a flow cytometer (FACSort; Becton Dickinson). An electronic gate was formed using forward and side scatter, and within the gate 15,000 cells were acquired. The number of fluorescent cells was determined after quadrants were set based on cells from uninfected wells. The number of fluorescent cells in a well infected with virus alone was designated 100% infection. The percentage of reduction in the number of fluorescent cells (percent neutralization) was determined for each plasma sample as described by Trkola et al. (35). All plasma samples were heat inactivated at 56°C for 30 min before use.
All plasma samples were tested for neutralization activity at a 1/10 dilution. Since HIV-1 inhibition due to undefined plasma components may be seen if a lesser dilution of plasma is used, IgG antibodies from plasma samples from two women (40W and 43W) were purified and tested against the respective virus. IgG was purified from 0.7 ml of plasma by using a protein A column according to the manufacturer's instructions (IgG purification kit; Bangalore Genei, India). Proteins in all fractions collected during elution were quantitated by Lowry's method (protein estimation kit; Bangalore Genei, India), and protein-rich fractions were pooled. The protein pool (IgG) was dialyzed in distilled water for 48 h. After dialysis, IgG was freeze-dried and resuspended in 0.3 ml phosphate buffer (0.01 M; pH 7.2). Before the neutralization assay, purified IgG along with undiluted plasma was retested by ELISA for anti-HLA antibodies. The same plasma samples (40W and 43W) were also tested for their HIV-1-neutralizing activities in the presence of complement (serum samples from five healthy individuals were pooled and used as a complement source) as described previously (30, 31, 40). Equal volumes of inactivated and 1/10-diluted test plasma, the respective virus, and undiluted complement were incubated for 1 h at 37°C under a 5% CO2 atmosphere during the neutralization assay as described by Spear et al. (30).
A pool of four plasma samples derived from HIV-infected individuals that showed neutralizing antibodies against the primary HIV-1 isolate (VB49) was used as a reference positive control in all the assays.
A pool of plasma samples from 12 healthy, HIV-seronegative individuals was tested as a negative control in all experiments to determine the background response. IgG purified from the negative control was tested along with the IgG from the test plasma. Complement was added to the negative control as well as to the test plasma when the neutralization assay was carried out in the presence of complement.
Determination of the extent of HLA proteins incorporated by HIV-1 and detection of the reactivity of anti-HLA antibody-positive plasma. The primary HIV-1 isolate (VB49) was cultured in PBMCs (12 x 106) derived from two healthy individuals (donors 1 and 2) as described above. Uninfected PBMCs (12 x 106) from both donors were also cultured as a control. The culture supernatants derived from infected cells (test) or uninfected cells (control) were passed through a 0.22-µm-pore-size filter and ultracentrifuged at 40,000 x g for 4 h. The pellet was resuspended in 0.4 ml phosphate buffer (0.05 M; pH 7.0) and lysed with an equal amount of lysis buffer (1:1:1 mixture of Triton X-100, dipotassium EDTA, and Tween 20). The HIV-1 capsid (p24) protein in the lysate was quantitated with a commercial ELISA kit (Vironostika HIV-1 antigen micro-ELISA system; Biomerieux, The Netherlands). HLA proteins were quantitated using the ELISA protocol described by Santoso et al. (27) with minor modifications. ELISA strips were coated with an anti-mouse IgG antibody (5 µg/ml). After overnight incubation at 4°C, the strips were washed, and antibody W6/32 (a monoclonal antibody of mouse origin that recognizes nonpolymorphic regions of HLA class I A, B, and C alleles; Biodesign International) was added as a capture antibody (2 µg/well). After incubation for 2 h at 37°C, the strips were washed and blocked using 5% bovine serum albumin. The lysate was then added, and HLA proteins bound to anti-HLA antibodies were detected using a biotin-labeled, anti-β2 microglobulin antibody (Fitzgerald International), horseradish peroxidase-conjugated streptavidin, and 3, 3', 5, 5'-tetramethylbenzidine-H2O2. The reaction was stopped by 2 N H2SO4, and absorbance was measured at 450 nm after the absorbance value of the blank well was subtracted. Serial dilutions (200, 100, 50, 25, and 12.5 ng/ml) of purified HLA protein (a gift from GTI, Brookfield, WI) were tested along with test samples, and a standard curve was prepared. The amount of HLA proteins in the test sample was determined by using the standard curve.
To determine whether anti-HLA antibody-positive plasma contains antibodies that bind to HLA proteins incorporated by HIV-1, plasma samples from two women (28W and 49W) were incubated with HIV-1 cultured in their respective husbands' (28H and 49H) PBMCs and also in autologous PBMCs. The virus was also incubated with pooled plasma samples from healthy, anti-HLA antibody-negative individuals (negative control) and with pooled plasma samples from HIV-seropositive individuals (positive control). The virus-plasma mixture was added and incubated in a well coated with rabbit anti-human IgG. The well was washed to remove unbound material after incubation, and virus lysis buffer was added to the well. The presence of bound virus was confirmed by detecting HIV-1 p24 protein in the lysate using a commercially available ELISA kit (Vironostika HIV-1 antigen micro-ELISA system; Biomerieux, The Netherlands).
|
|
|---|
|
View this table: [in a new window] |
TABLE 1. Detection of anti-HLA antibodies by ELISA
|
![]() View larger version (46K): [in a new window] |
FIG. 1. Detection of binding of antibodies to lymphocytes by flow cytometry. Results for eight couples are presented. Each woman's plasma (test) was incubated with autologous PBMCs (W) and her husband's PBMCs (H) (2 x 105) at a 1/20 dilution. PBMCs were also incubated with a pool of plasma obtained from 12 healthy, HIV-seronegative individuals (control). Bound antibodies were detected using FITC-labeled anti-human IgG. The husband's lymphocytes showed higher fluorescence intensity (x axis) when treated with the wife's plasma (solid histograms) than when treated with the control (open histograms). The asterisked number in the upper right corner of each panel is the sMFI, calculated as the MFI for the test divided by the MFI for the control.
|
![]() View larger version (15K): [in a new window] |
FIG. 2. Confirmation of the HLA specificity of antibodies that bind to the husband's PBMCs. IgG antibodies against HLA class I, HLA class II, and CMV in plasma samples from three women—40W (A), 43W (B), and 65W (C)-before and after incubation with their respective husbands' PBMCs were measured by ELISA. For anti-HLA antibodies, the plasma samples of 40W and 43W were tested at a 1/20 dilution, whereas that of 65W was tested at a 1/2 dilution. All plasma samples were tested at a 1/100 dilution for antibodies against CMV. The absorbance values are shown on the y axis. All plasma samples showed >75% reductions in absorbance values for antibodies against HLA classes I and II after incubation with the respective husbands' PBMCs, whereas no reduction was observed in the absorbance for antibodies against CMV.
|
![]() View larger version (14K): [in a new window] |
FIG. 3. Anti-HLA antibodies do not show HIV-1-neutralizing activity. (A) Anti-HLA antibody-positive plasma samples from 14 women were tested for neutralizing activity against HIV-1 cultivated in their respective husbands' PBMCs by a GHOST cell assay. Neutralizing activity (percent reduction in infection compared to infection with virus alone) is shown on the y axis. The reference positive control (a pool of four plasma samples from HIV-infected individuals that showed HIV-1-neutralizing activity) showed >90% neutralization, whereas the reference negative control (a pool of plasma samples from 12 healthy, HIV-seronegative individuals) showed a background response of <30%. Shown are percentages of neutralization by plasma samples from six participants with antibodies against HLA classes I and II (A1), two participants with antibodies to HLA class I alone (A2), and six participants with antibodies to HLA class II alone (A3). All anti-HLA antibody-positive plasma samples were tested at a 1/10 dilution. (B) Percentages of neutralization by purified IgG from women 40W and 43W, tested at a 1/2 dilution. (C) Percentages of neutralization by plasma from women 40W and 43W tested at a 1/10 dilution in the presence of complement. Data in panels A and B are means and standard deviations from two independent experiments.
|
HLA proteins were incorporated by HIV-1, and binding of antibodies to HLA proteins was detected.
The HIV-1 lysate derived from in vitro-infected PBMCs from donors 1 and 2 contained 1,637 and 906 ng of p24 protein/ml and 150 and 224 ng of HLA class I proteins/ml, respectively. The HIV-1 culture contains cell membrane microvesicles that carry host HLA proteins (4). Therefore, the amount of HLA proteins in the control was determined and subtracted from the amount of HLA proteins detected in HIV-1 culture. The molar ratio of HLA class I proteins to HIV-1 p24 was 0.017 for donor 1 and 0.054 for donor 2 (Table 2). Since there are an average of 2,500 capsid molecules per virion (10, 36), our estimate of the HLA/p24 ratio suggests the acquisition of 42 to 135 HLA class I molecules per virion. Since there are
14 envelope trimers per HIV-1 virion (10), our data suggest that the virions of the primary HIV-1 isolate may carry more HLA molecules than envelope trimers.
|
View this table: [in a new window] |
TABLE 2. Incorporation of HLA class I proteins by a primary HIV-1 isolate
|
![]() View larger version (15K): [in a new window] |
FIG. 4. Binding of anti-HLA antibodies to HIV-1 cultured in the husband's PBMCs, but not to HIV-1 cultured in autologous PBMCs, after incubation with anti-HLA antibody-positive plasma from the wife. Each wife's plasma (28W and 49W) was incubated separately with HIV-1 cultured in her husband's (28H and 49H, respectively) PBMCs or autologous PBMCs. The virus was also incubated with pooled plasma samples from healthy, anti-HLA antibody-negative individuals (negative control) and from HIV-seropositive individuals (positive control). The virus-plasma mixture was added and incubated in a well coated with rabbit anti-human IgG. After a wash, the virus bound to the well was lysed, and ELISA was used for detection of HIV-1 p24 antigen. Each wife's plasma contained antibodies that specifically bound to HIV-1 cultured in her husband's PBMCs but did not bind to HIV-1 cultured in autologous PBMCs.
|
|
|
|---|
For any clinical application of anti-HLA antibody-mediated HIV-1 neutralization, the diversity of HLA proteins needs to be taken into account. It has been proposed that by appropriately selecting HLA alleles, it may be feasible to induce an immune response that can overcome HLA diversity in a given population (13). The strategy may be particularly useful for the protection of monogamous partners of HIV-1-seropositive individuals. Induction of anti-HLA antibodies was found safe for more than 2,000 women undergoing leukocyte immunotherapy to prevent recurrent spontaneous abortions (22). The major advantage of alloimmunization as a strategy for preventing HIV-1 infection is that it is likely to be independent of HIV-1 subtypes and genetic variations. We investigated the infectivity of HIV-1 in the presence of anti-HLA antibodies that can bind to HLA proteins present in the HIV-1 envelope.
Plasma samples from multiparous women that produced antibodies against the polymorphic regions of HLA alleles expressed by their husbands were obtained. Each woman's plasma was tested against a primary HIV-1 isolate that was cultured in the PBMCs of her husband so that the test virus carried the husband's HLA alleles. No reduction in viral infectivity was shown by any of 14 anti-HLA antibody-positive plasma samples (Fig. 3).
Factors such as inadequate levels of anti-HLA antibodies in the plasma or inadequate incorporation of HLA molecules in the virus envelope may be responsible for the lack of neutralizing activity. In a study reported by Leith et al. (14), anti-HLA antibodies were derived from women who had been immunized with multiple injections of 108 allogeneic lymphocytes. We obtained anti-HLA antibodies from women who were sensitized by exposure to semiallogeneic fetal cells that passed through the maternal-fetal barrier. This may influence the titer of anti-HLA antibodies. We therefore purified and concentrated IgG from two plasma samples and tested it at the highest possible concentration. However, no evidence for any HIV-1-neutralizing activity of anti-HLA antibodies was obtained (Fig. 3B).
In a study reported by Spruth et al. (31) and Wilfingseder et al. (40), significant neutralization of HIV-1 IIIB derived from cell lines was observed in the presence of anti-HLA antibodies and complement. The virus inhibition reported in these studies could be due to complement-mediated viral lysis (40). It has been shown that HIV-1 derived from T-cell lines is highly susceptible to complement, due to low incorporation of complement-regulatory proteins (CD55 and CD59) (32). Another mechanism for enhanced neutralization in the presence of complement may be higher steric hindrance of viral entry by the complement-antibody complex than by the antibody alone, as described for respiratory syncytial virus (41). We tested anti-HLA antibodies against an HIV-1 isolate in the presence of complement; however, no evidence of HIV-1 neutralization was observed (Fig. 3C). This finding might be due to the resistance of the primary HIV-1 isolate cultured in PBMCs to complement-mediated lysis. It has been shown that primary HIV-1 isolates incorporate complement-regulatory proteins (25, 26, 32) that can confer resistance to complement-mediated viral lysis.
The prerequisite for anti-HLA antibody-mediated HIV-1 neutralization is the acquisition of HLA molecules by HIV-1. It has been reported that the amount of HLA proteins acquired by HIV-1 may differ depending on the viral strain and the type of host cell (7). In our study, the molar ratio of HLA class I protein to HIV-1 capsid (p24) protein (0.017 and 0.054 for PBMC donors 1 and 2, respectively [Table 2]) suggested that the virus may carry more HLA molecules than gp160 trimers. Similar findings have been reported previously (1a, 36). Despite the incorporation of a significant number of HLA molecules by HIV-1 virions, anti-HLA antibodies were unable to reduce viral infectivity. Although anti-HLA antibodies bound to HIV-1 (Fig. 4), no evidence was obtained for their virus-neutralizing activity (Fig. 3).
The lack of HIV-1-neutralizing activity by anti-HLA antibodies may probably be attributed to the difference in size between HLA and HIV-1 envelope proteins. The HIV-1 gp160 trimer is 483 kDa, whereas HLA class I and II molecules are 57 and 61 kDa, respectively. The binding of IgG antibody (150 kDa) to HLA class I and II molecules can form a complex of
210 kDa. Since the HIV-1 envelope molecule is relatively large and it forms a spike that bulges out of the membrane, the binding of anti-HLA antibodies may not interfere with the interaction between viral gp160 and the CD4 receptor. Although this could be anticipated without experimental investigation, the complexity of the mechanism of viral entry into the target cell, experimental evidence (8, 9, 14, 30, 31, 40), and the potential advantage of this approach (13) prompted further investigation. This study shows the lack of HIV-1-neutralizing activity by anti-HLA antibodies.
Alloimmune recognition leads to the induction of various responses, such as generation of anti-HLA antibodies, secretion of β-chemokines (3, 37-39), lymphoproliferative responses (20), formation of anti-CCR5 antibodies (3, 39), and secretion of RNases (24). Although no evidence was obtained for a protective role of anti-HLA antibodies against HIV-1, one or more of these responses might be contributing to the evidence of alloimmune-response-mediated protection against HIV-1.
We thank the Indian Council of Medical Research (ICMR), Government of India, for supporting S. K. Lakhashe with a research fellowship.
Published ahead of print on 17 October 2007. ![]()
|
|
|---|
3 inhibits
1-mediated hemagglutination by steric hindrance. J. Virol. 75:6625-6634.
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2010 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»